City Research Online

Optimising subjective anterior eye grading precision

Vianya-Estopa, M., Nagra, M., Cochrane, A. , Retallic, N., Dunning, D., Terry, L., Lloyd, A., Wolffsohn, J. S., Alderson, A., Mouat, G., McDonnell, C., Murphy, O., Huntjens, B. ORCID: 0000-0002-4864-0723, Mayhem, M., Martin, E., Sweeney, L., Evans, K., Naroo, S., Conway, R., Simo, L., Maldonado-Codina, C., Mallon, C., Underwood, J., Trivedy, K. & Joshi, M. (2020). Optimising subjective anterior eye grading precision. Contact Lens and Anterior Eye, 43(5), pp. 489-492. doi: 10.1016/j.clae.2020.03.006

Abstract

Purpose: To establish the optimum grading increment which ensured parity between practitioners while maximising clinical precision.

Methods: Second year optometry students (n=127, 19.5 ± 1.4 years, 55% female) and qualified eye care practitioners (n=61, 40.2 ±14.8 years, 52% female) had 30 seconds to grade each of bulbar, limbal and palpebral hyperaemia of the upper lid of 4 patients imaged live with a digital slit lamp under 16x magnification, diffuse illumination, with the image projected on a screen. The patients were presented in a randomised sequence 3 times in succession, during which the graders used the Efron printed grading scale once to 0.1 precision, once to 0.5 precision and once to the nearest integer grade in a randomised order. Graders were masked to their previous responses.

Results: For most grading conditions less than 20% of clinicians showed a ≤0.1 difference in grade from the mean. In contrast, more than 50% of the student graders and 40% of experienced graders showed a difference in grade from the mean within 0.5 for all conditions under measurement. Student precision in grading was better with both 0.1 and 0.5 grading precision than grading to the nearest unit, except for limbal hyperaemia where they performed more accurately with 0.5 unit precision grading. Limbal grading precision was not affected by grading step precision for experienced practitioners, but 0.1 and 0.5 grading precision were both better than 1.0 grading precision for bulbar hyperaemia and 0.1 grading precision was better than 0.5 grading precision and both were better than 1.0 grading precision for palpebral hyperaemia.

Conclusion: Although narrower intervals scales maximise the ability to detect smaller clinical changes, the grading increment should not exceed one standard deviation of the discrepancy between measurements. Therefore, 0.5 grading increments are recommended for subjective anterior eye physiology grading (limbal, bulbar and palpebral redness).

Publication Type: Article
Additional Information: © 2020 British Contact Lens Association. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/
Publisher Keywords: Grading, Hyperaemia, Student, Eye-care practitioner, Scale increments
Subjects: R Medicine > RE Ophthalmology
Departments: School of Health & Psychological Sciences > Optometry & Visual Sciences
SWORD Depositor:
[thumbnail of Optimising%20Subj%20Ant%20Eye%20Grading%20Precision.%20CLEAN.pdf]
Preview
Text - Accepted Version
Download (196kB) | Preview

Export

Add to AnyAdd to TwitterAdd to FacebookAdd to LinkedinAdd to PinterestAdd to Email

Downloads

Downloads per month over past year

View more statistics

Actions (login required)

Admin Login Admin Login