Validating and updating the OHTS-EGPS model predicting 5-year glaucoma risk among ocular hypertension patients using electronic records
Wright, D. M. ORCID: 0000-0001-8948-3691, Azuara-Blanco, A. ORCID: 0000-0002-4805-9322, Cardwell, C. , Montesano, G., Crabb, D. P. ORCID: 0000-0001-8754-3902, Gazzard, G., King, A. J., Hernández, R. ORCID: 0000-0003-2619-8230, Morgan, J. E., Higgins, B., Takwoingi, Y. ORCID: 0000-0002-5828-9746, Booth, A., Rowlands, A., McNaught, A., Scott, A., King, A., Azuara-Blanco, A., Higgins, B., Cardwell, C., Dimitriou, C., Wright, D. M., Crabb, D. P., Ahmed, F., Montesano, G. ORCID: 0000-0002-9148-2804, Gazzard, G., Wu, H., Morgan, J. E., Weir, L., French, L., Nagar, M., Rafiq, O., Sebastian, R., Hernández, R., Watson, V. & Takwoingi, Y. (2024). Validating and updating the OHTS-EGPS model predicting 5-year glaucoma risk among ocular hypertension patients using electronic records. Ophthalmology Glaucoma, doi: 10.1016/j.ogla.2024.10.009
Abstract
Objective
To validate and update the OHTS-EGPS model predicting risk of conversion from OHT to glaucoma using electronic medical records (EMR).
Design
Evaluation and update of a risk prediction algorithm using EMRs and linked visual field (VF) tests.
Participants
Newly diagnosed OHT patients attending hospital glaucoma services in England. Inclusion criteria: IOP 22-32 mmHg (either eye); normal baseline VF test, defined as Glaucoma Hemifield Test (GHT) ‘within normal range’ in a reliable VF test; at least two VF tests in total; no significant ocular co-morbidities.
Methods
Risk factors: age, ethnicity, sex, IOP, vertical cup-to-disc ratio, central corneal thickness, VF pattern standard deviation, family history of glaucoma, systemic hypertension, diabetes mellitus, glaucoma treatment. Glaucoma conversion was defined as two consecutive and reliable VF tests with GHT ‘outside normal limits’ and/or need for glaucoma surgery. For validation, the OHTS-EGPS model was applied to predict a patient’s risk of developing glaucoma in 5 years. In the updating stage, the OHTS-model was re-fitted by re-estimating the baseline hazard and regression coefficients. The updated model was cross-validated and several variants were explored.
Main Outcome Measures
Measures of discriminative ability (c-index) and calibration (calibration slope) were calculated and pooled across hospitals using random effects meta-analysis.
Results
From a total of 138,461 patients from ten hospital glaucoma services in England 9030 patients with OHT fitted the inclusion criteria. A total of 1530 (16.9%) patients converted to glaucoma during this follow-up period. The OHTS-EGPS model provided a pooled c-index of 0.61 (95% confidence interval: 0.60, 0.63), ranging from 0.55 to 0.67 between hospitals. The pooled calibration slope was 0.45 (0.38, 0.51), ranging from 0.25 to 0.64 among hospitals. The overall re-fitted model performed better than the OHTS-EGPS model, with a pooled c-index of 0.67 (0.65, 0.69), ranging from 0.65 to 0.75 between hospitals.
Conclusions
We performed an external validation of the OHTS-EGPS model in a large English population. Re-fitting the model achieved modest improvements in performance. Given the poor performance of the OHTS-EGPS model in our population, one should use caution in its application to populations that differ from those in the OHTS and EGPS.
Publication Type: | Article |
---|---|
Additional Information: | © 2024. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/ |
Subjects: | R Medicine > RE Ophthalmology |
Departments: | School of Health & Psychological Sciences School of Health & Psychological Sciences > Optometry & Visual Sciences |
SWORD Depositor: |
This document is not freely accessible until 4 November 2025 due to copyright restrictions.
Available under License Creative Commons Attribution Non-commercial No Derivatives.
To request a copy, please use the button below.
Request a copyExport
Downloads
Downloads per month over past year