Does the Swedish Interactive Threshold Algorithm (SITA) accurately map visual field loss attributed to vigabatrin?
Conway, M. L., Hosking, L. S., Zhu, H. & Cubbidge, P. R. (2014). Does the Swedish Interactive Threshold Algorithm (SITA) accurately map visual field loss attributed to vigabatrin?. BMC Ophthalmology, 14(1), 166-. doi: 10.1186/1471-2415-14-166
Abstract
Purpose
Vigabatrin (VGB) is an anti-epileptic medication which has been linked to peripheral constriction of the visual field. Documenting the natural history associated with continued VGB exposure is important when making decisions about the risk and benefits associated with the treatment. Due to its speed the Swedish Interactive Threshold Algorithm (SITA) has become the algorithm of choice when carrying out Full Threshold automated static perimetry. SITA uses prior distributions of normal and glaucomatous visual field behaviour to estimate threshold sensitivity. As the abnormal model is based on glaucomatous behaviour this algorithm has not been validated for VGB recipients. We aim to assess the clinical utility of the SITA algorithm for accurately mapping VGB attributed field loss.
Methods
The sample comprised one randomly selected eye of 16 patients diagnosed with epilepsy, exposed to VGB therapy. A clinical diagnosis of VGB attributed visual field loss was documented in 44% of the group. The mean age was 39.3 years ± 14.5 years and the mean deviation was -4.76 dB ±4.34 dB. Each patient was examined with the Full Threshold, SITA Standard and SITA Fast algorithm.
Results
SITA Standard was on average approximately twice as fast (7.6 minutes) and SITA Fast approximately 3 times as fast (4.7 minutes) as examinations completed using the Full Threshold algorithm (15.8 minutes). In the clinical environment, the visual field outcome with both SITA algorithms was equivalent to visual field examination using the Full Threshold algorithm in terms of visual inspection of the grey scale plots , defect area and
defect severity.
Conclusions
Our research shows that both SITA algorithms are able to accurately map visual field loss attributed to VGB. As patients diagnosed with epilepsy are often vulnerable to fatigue, the time saving offered by SITA Fast means that this algorithm has a significant advantage for use with VGB recipients.
Publication Type: | Article |
---|---|
Additional Information: | available under CC BY 2.0 |
Subjects: | R Medicine > RE Ophthalmology |
Departments: | School of Health & Psychological Sciences > Optometry & Visual Sciences |
SWORD Depositor: |
Available under License : See the attached licence file.
Download (593kB) | Preview
Download (25kB)
Export
Downloads
Downloads per month over past year