City Research Online

Reflectance Photoplethysmography as Non-Invasive Monitoring of Tissue Blood Perfusion.

Abay, T. & Kyriacou, P. A. (2015). Reflectance Photoplethysmography as Non-Invasive Monitoring of Tissue Blood Perfusion.. IEEE Trans Biomed Eng, 62(9), pp. 2187-2195. doi: 10.1109/tbme.2015.2417863

Abstract

In the last decades Photoplethysmography (PPG) has been used as noninvasive technique for monitoring arterial oxygen saturation by Pulse Oximetry (PO), whereas Near Infrared Spectroscopy (NIRS) has been employed for monitoring tissue blood perfusion. While NIRS offers more parameters to evaluate oxygen delivery and consumption in deep tissues, PO only assesses the state of oxygen delivery. For a broader assessment of blood perfusion, this paper explores the utilization of dual-wavelength PPG by using the pulsatile (AC) and continuous (DC) PPG for the estimation of arterial oxygen saturation (SpO2) by conventional PO. Additionally, the Beer-Lambert law is applied to the DC components only for the estimation of changes in deoxy-hemoglobin (HHb), oxy-hemoglobin (HbO2) and total hemoglobin (tHb) as in NIRS. The system was evaluated on the forearm of 21 healthy volunteers during induction of venous occlusion (VO) and total occlusion (TO). A reflectance PPG probe and NIRS sensor were applied above the brachioradialis, PO sensors were applied on the fingers, and all the signals were acquired simultaneously. While NIRS and forearm SpO2 indicated VO, SpO2 from the finger did not exhibit any significant drop from baseline. During TO all the indexes indicated the change in blood perfusion. HHb, HbO2 and tHb changes estimated by PPG presented high correlation with the same parameters obtained by NIRS during VO (r2=0.960, r2=0.821 and r2 =0.974 respectively) and during TO (r2=0.988, r2=0.940 and r2=0.938 respectively). The system demonstrated the ability to extract valuable information from PPG signals for a broader assessment of tissue blood perfusion.

Publication Type: Article
Additional Information: © 2015 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
Publisher Keywords: Beer-Lambert law, near infrared spectroscopy (NIRS), optical sensors, photoplethysmography, physiological monitoring, pulse oximetry.
Subjects: Q Science > QA Mathematics
Departments: School of Science & Technology
School of Science & Technology > Engineering
SWORD Depositor:
[thumbnail of TBME-01392-2014.R1-preprint.pdf]
Preview
PDF - Accepted Version
Download (919kB) | Preview

Export

Add to AnyAdd to TwitterAdd to FacebookAdd to LinkedinAdd to PinterestAdd to Email

Downloads

Downloads per month over past year

View more statistics

Actions (login required)

Admin Login Admin Login