Computer Aided Design of Process Tomography Capacitance Electrode System for Flow Imaging
Khan, S. ORCID: 0000-0001-5589-6914 & Abdullah, F. (1991). Computer Aided Design of Process Tomography Capacitance Electrode System for Flow Imaging. In: Grattan, K. T. V. ORCID: 0000-0003-2250-3832 (Ed.), Sensors, Technology, Systems and Applications. (pp. 209-214). Florida, USA: CRC Press.
Abstract
This paper involves various aspects and results for the computer aided design of capicitance electrode systmes used for imaging and measurement of two-phase flows. Various 2D finite element models of a 12-electrode system have been investigated to show the effects of a range of design parameters on system performance. Recommendations have been made for the selection of some these parameters which could give desirable system performance.
Publication Type: | Book Section |
---|---|
Additional Information: | This is an Accepted Manuscript of a book chapter published by Routledge/CRC Press in Sensors, Technology, Systems and Applications on 1 Oct 1991, available online: https://www.crcpress.com/ |
Subjects: | Q Science > QA Mathematics > QA75 Electronic computers. Computer science T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Departments: | School of Science & Technology > Engineering |
Download (1MB) | Preview