City Research Online

Non-equilibrium CFD simulation of the wet-to-dry expansion of the siloxane MM in a converging–diverging nozzle

Ogrodniczak, P. & White, M. ORCID: 0000-0002-7744-1993 (2023). Non-equilibrium CFD simulation of the wet-to-dry expansion of the siloxane MM in a converging–diverging nozzle. Applied Thermal Engineering, 234, article number 121158. doi: 10.1016/j.applthermaleng.2023.121158

Abstract

Wet-to-dry organic Rankine cycles could generate 30% higher power outputs in the temperature range of 150 to 250 °C compared to existing single-phase cycles. Since the expansion is only partially wet, turboexpanders could potentially be applied provided that the wet portion of the expansion is confined to the stator to avoid erosion in the rotor. To assess the feasibility of achieving complete evaporation in the stator, two-dimensional non-equilibrium numerical simulations of the wet-to-dry expansion of siloxane MM in a covering–diverging nozzle are performed for the first time. The simulation setup is first validated against published experimental data, and a sensitivity study is conducted concerning the selected interphase models. The model is then applied to simulate expansions from inlet pressures ranging from 478 to 1250 kPa and vapour qualities from 0.1 to 0.5. Moreover, the droplet number density was varied between 10¹⁰ and 10¹⁴. The results show that the evaporation rate, the extent of non-equilibrium effects and the flow’s spatial uniformity are predominantly dependent on the droplet size. Expansions beginning with droplets smaller than 20µm resulted in complete mixture evaporation and negligible non-equilibrium effects in almost all investigated cases. For larger droplets, ranging from 40 to 100µm, full evaporation could only be achieved for inlet pressures above 750 kPa and inlet qualities above 0.3, whereas for lower pressures, the outlet vapour quality varied between 80 and 90%. For droplets larger than 200µm, there is a significant delay in evaporation resulting in outlet quality typically between 40 and 70%. Larger droplet flows are characterised by substantial velocity slip, temperature difference, phase separation and lateral velocity variations. Having said this, droplet breakup analysis indicates that droplets larger than 100µm are likely to undergo breakup, which could enhance the evaporation rate; however, this requires further investigation. In conclusion, high inlet pressures and high inlet qualities are preferred from the perspective of ensuring dry-vapour conditions at the nozzle outlet.

Publication Type: Article
Additional Information: © 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
Publisher Keywords: Two-phase expansion, Wet-to-dry cycle, Flash boiling, Organic Rankine cycle, Non-equilibrium
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TJ Mechanical engineering and machinery
Departments: School of Science & Technology > Engineering
SWORD Depositor:
[thumbnail of 1-s2.0-S1359431123011870-main.pdf]
Preview
Text - Published Version
Available under License Creative Commons: Attribution International Public License 4.0.

Download (2MB) | Preview

Export

Add to AnyAdd to TwitterAdd to FacebookAdd to LinkedinAdd to PinterestAdd to Email

Downloads

Downloads per month over past year

View more statistics

Actions (login required)

Admin Login Admin Login